收藏切换
Simulation study on critical condition of current density for ablation of high voltage cable buffer layer to insulating shield layer
收藏切换
PDF
Yekun MEN1, Ke ZHANG2, Wei GUO1, Hongquan JI1, Zhigang REN1, Jingcheng ZHANG3, Jian GAO2
Insulating Materials | 2025, 58(3) : 109 - 116
Less
收藏切换
Insulating Materials | 2025, 58(3): 109-116
Special Issue on Advanced Cable Insulation
Simulation study on critical condition of current density for ablation of high voltage cable buffer layer to insulating shield layer
Full
Yekun MEN1, Ke ZHANG2, Wei GUO1, Hongquan JI1, Zhigang REN1, Jingcheng ZHANG3, Jian GAO2
Affiliations
  • 1 Electric Power Research Institute of State Grid Beijing Electric Power Company, Beijing 100075, China
  • 2 Xi′an Jiaotong University, Xi′an 710049, China
  • 3 State Grid Beijing Electric Power Company, Beijing 100075, China
Published: 2025-03-20 doi: 10.16790/j.cnki.1009-9239.im.2025.03.012
Outline
收藏切换

To investigate the critical conditions of high voltage cable buffer layer ablation, the types of insulation shielding damage caused by actual cable ablation were summarized in this paper. A three-dimensional asymmetric high-voltage cable model was established by finite element simulation. The ablation development process of high-voltage cables under both dry and wet conditions, as well as the mechanisms of their damage to insulation shielding, were studied separately. The difficulty of ablation under the two conditions was compared and analyzed. The results show that damage under dry condition is attributed to current-induced thermal effects caused by prolonged poor contact. When poor contact extends to 7.5 m, the surface current density on the buffer layer reaches as high as 442 A/m2, and the temperature reaches high as 200℃ within the buffer layer. Damage under wet condition arises from current-induced thermal effects caused by the high resistance products from electrochemical corrosion, and these products can penetrate areas where current and temperature are concentrated within the buffer layer. When the coverage rate of white powder reaches 97.9%, the surface current density on the buffer layer is up to 416 A/m2. Simulation results align closely with actual dissolution observed in faulty cables affected by ablation, thus validating our analysis findings presented in this paper.

buffer layer ablation  /  insulation shield layer  /  current heating effect  /  electrochemical corrosion  /  finite element simulation
Yekun MEN, Ke ZHANG, Wei GUO, Hongquan JI, Zhigang REN, Jingcheng ZHANG, Jian GAO. Simulation study on critical condition of current density for ablation of high voltage cable buffer layer to insulating shield layer[J]. Insulating Materials, 2025 , 58 (3) : 109 -116 . DOI: 10.16790/j.cnki.1009-9239.im.2025.03.012
Year 2025 volume 58 Issue 3
PDF
97
44
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2025.03.012
  • Receive Date:2024-05-09
  • Online Date:2025-11-07
  • Published:2025-03-20
Article Data
Affiliations
History
  • Received:2024-05-09
  • Revised:2024-08-12
Funding
Affiliations
    1 Electric Power Research Institute of State Grid Beijing Electric Power Company, Beijing 100075, China
    2 Xi′an Jiaotong University, Xi′an 710049, China
    3 State Grid Beijing Electric Power Company, Beijing 100075, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2025.03.012
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT