收藏切换
DGA analysis on ester insulating liquid impregnated paper system for transformer under simulated low temperature thermal fault
收藏切换
PDF
Yaoxiang MA1, Yuan WANG1, Kexin PAN1, Haoyong SONG2, Wei WANG2, Yang XU1
Insulating Materials | 2023, 56(3) : 84 - 92
Less
收藏切换
Insulating Materials | 2023, 56(3): 84-92
Test and Analysis
DGA analysis on ester insulating liquid impregnated paper system for transformer under simulated low temperature thermal fault
Full
Yaoxiang MA1, Yuan WANG1, Kexin PAN1, Haoyong SONG2, Wei WANG2, Yang XU1
Affiliations
  • 1State Key Laboratory of Electrical Insulation and Power Equipment, Xi′an Jiaotong University, Xi′an 710049, China
  • 2Guangzhou Power Supply Bureau, Guangdong Power Grid Co., Ltd., Guangzhou 510000, China
Published: 2023-03-20 doi: 10.16790/j.cnki.1009-9239.im.2023.03.013
Outline
收藏切换

The environment-friendly insulating fluid for transformer has developed rapidly in recent years, insulating liquids such as natural ester, synthetic ester, and modified ester have become the research focus of new insulating material for transformer. With their applications in 110 kV and above transformers, the dissolved gas analysis (DGA) fault diagnosis method of mineral oil filled transformer is no longer suitable for the ester insulating liquid filled transformer. In this paper, a thermal fault simulation system with temperature difference between copper and liquid was designed to simulate the low temperature thermal fault. The soybean, rapeseed, camellia based natural ester, synthetic ester, and palm based modified ester insulating liquids were used as research object, the experimental results of dissolved gas in pure liquid and liquid-paper insulating system under 200℃ and 300℃ low temperature thermal fault were analyzed, and the applicability of the IEC ratio method and Duval pentagon method were discussed. The results show that the IEC ratio method is still applicable to 200℃ and 300℃ low temperature thermal fault diagnosis of natural esters and synthetic ester. The Duval pentagon method can be used to recognize the low temperature thermal fault of natural esters and synthetic ester after adjustment. However, the DGA results of modified ester are inconsistent to those of mineral oil and natural esters, and the Duval pentagon method based on mineral oil is not suitable for the low temperature thermal fault diagnosis of palm based modified ester.

transformer  /  ester insulating liquid  /  low temperature thermal fault  /  dissolved gas analysis  /  fault diagnosis
Yaoxiang MA, Yuan WANG, Kexin PAN, Haoyong SONG, Wei WANG, Yang XU. DGA analysis on ester insulating liquid impregnated paper system for transformer under simulated low temperature thermal fault[J]. Insulating Materials, 2023 , 56 (3) : 84 -92 . DOI: 10.16790/j.cnki.1009-9239.im.2023.03.013
Year 2023 volume 56 Issue 3
PDF
264
130
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2023.03.013
  • Receive Date:2021-12-14
  • Online Date:2025-11-21
  • Published:2023-03-20
Article Data
Affiliations
History
  • Received:2021-12-14
  • Revised:2022-01-25
Funding
Affiliations
    1State Key Laboratory of Electrical Insulation and Power Equipment, Xi′an Jiaotong University, Xi′an 710049, China
    2Guangzhou Power Supply Bureau, Guangdong Power Grid Co., Ltd., Guangzhou 510000, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2023.03.013
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT