收藏切换
Effect of Repetitive Impulsive Voltage Rise time on PDIV of Turn to Turn Insulation for Low-voltage Random-wound Inverter-fed Motor
收藏切换
PDF
Chizhou CHENG, Peng WANG, Xiang LI
Insulating Materials | 2021, 54(8) : 67 - 73
Less
收藏切换
Insulating Materials | 2021, 54(8): 67-73
Insulation Technology
Effect of Repetitive Impulsive Voltage Rise time on PDIV of Turn to Turn Insulation for Low-voltage Random-wound Inverter-fed Motor
Full
Chizhou CHENG, Peng WANG, Xiang LI
Affiliations
  • College of Electrical Engineering, Sichuan University, Chengdu 610065, China
Published: 2021-08-20 doi: 10.16790/j.cnki.1009-9239.im.2021.08.011
Outline
收藏切换

Partial discharge inception voltage (PDIV) under repetitive pulse voltage is an important parameter to evaluate the insulation performance of low-voltage random-wound inverter-fed motors. Different from the traditional sinusoidal voltage, the rise time and polarity of the impulse are critical parameters to be considered when PDIV test is carried out on the turn to turn insulation of the winding for inverter-fed motor at repetitive impulsive voltages. In this paper, the influence of repetitive impulsive voltage rise time on the PDIV and energy distribution features of turn to turn insulation for inverter-fed motors with three specification were investigated at repetitive impulse voltages with different impulse rise times (50 ns, 75 ns, 100 ns, and 200 ns), and the mechanism of variation of PDIV with different rise times was discussed. The results show that with the decrease of rise time, the PDIV of three motors decreases, and the maximum decline rate reaches 28.1%. The influence of repetitive pulse polarity on the PDIV test results of low-voltage random-wound inverter-fed motor is limited, indicating that both positive and negative can objectively reflect the PDIV performance of motor. With the increase of impulse rise time, the discharge energy in frequency domain moves from high frequency to low frequency. The research results are expected to provide reference for PDIV test of low voltage inverter-fed motor insulation and the revision of related standards.

inverter-fed motors  /  insulation systems  /  partial discharge  /  PDIV  /  frequency domain characteristics
Chizhou CHENG, Peng WANG, Xiang LI. Effect of Repetitive Impulsive Voltage Rise time on PDIV of Turn to Turn Insulation for Low-voltage Random-wound Inverter-fed Motor[J]. Insulating Materials, 2021 , 54 (8) : 67 -73 . DOI: 10.16790/j.cnki.1009-9239.im.2021.08.011
Year 2021 volume 54 Issue 8
PDF
133
62
Cite this Article
BibTeX
Article Info
doi: 10.16790/j.cnki.1009-9239.im.2021.08.011
  • Receive Date:2021-03-09
  • Online Date:2026-03-20
  • Published:2021-08-20
Article Data
Affiliations
History
  • Received:2021-03-09
  • Revised:2021-04-19
Funding
Affiliations
    College of Electrical Engineering, Sichuan University, Chengdu 610065, China
References
Share
https://castjournals.cast.org.cn/joweb/jycl/EN/10.16790/j.cnki.1009-9239.im.2021.08.011
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT