收藏切换
Methodological Study on the Determination of the Purity of Recombinant Human Basic Fibroblast Growth Factor by SEC-HPLC
收藏切换
PDF
Tingling FU1, Guihai HUANG1, Dong LAN2, Junfang SHI1, Qing LIANG1, *
Pharmacy Today | 2025, 35(8) : 590 - 592
Less
收藏切换
Pharmacy Today | 2025, 35(8): 590-592
Methodological Study on the Determination of the Purity of Recombinant Human Basic Fibroblast Growth Factor by SEC-HPLC
Full
Tingling FU1, Guihai HUANG1, Dong LAN2, Junfang SHI1, Qing LIANG1, *
Affiliations
  • 1.Langtai Biopharmaceutical Co., Ltd., Foshan, Guangdong 528225, China
  • 2.The General Hospital of Western Theater Command, Chengdu, Sichuan, 610083, China
Published: 2025-08-25 doi: 10.12048/j.issn.1674-229X.2025.08.005
Outline
收藏切换
OBJECTIVE

To establish a size exclusion high-performance liquid chromatography (SEC-HPLC) method for the determination of the purity of recombinant human basic fibroblast growth factor (rh-bFGF).

METHODS

The purity of rh-bFGF solution was determined using TSK G2000SWXL column and high-performance liquid chromatography, and the specificity, repeatability, precision, detection limit, stability, and durability of the method were evaluated.

RESULTS

The blank solvent has no interference with the rh-bFGF main peak, and the degradation impurities under various destruction conditions didn't interfere with the determination of the rh-bFGF peak, and the purity index of the rh-bFGF peak was greater than 990. The repeatability and intermediate precision experimental results showed that the separation degree of impurities and the rh-bFGF main peak was greater than 1.5, and the RSD was 0.36% and 0.64%, respectively. The detection limit was 0.185 μg·mL-1. The durability experiment results show that fluctuations in flow rate, column temperature, and wavelength had no effect on the detection results, and the RSD of each condition was less than 2.0%.

CONCLUSION

The SEC-HPLC method developed has the advantages of simple operation, accurate results, strong specificity, high stability and good applicability, and can be used for rh-bFGF purity determination.

high performance liquid chromatography (HPLC)  /  purity determination  /  method development  /  methodology validation
Tingling FU, Guihai HUANG, Dong LAN, Junfang SHI, Qing LIANG. Methodological Study on the Determination of the Purity of Recombinant Human Basic Fibroblast Growth Factor by SEC-HPLC[J]. Pharmacy Today, 2025 , 35 (8) : 590 -592 . DOI: 10.12048/j.issn.1674-229X.2025.08.005
Year 2025 volume 35 Issue 8
PDF
98
42
Cite this Article
BibTeX
Article Info
doi: 10.12048/j.issn.1674-229X.2025.08.005
  • Receive Date:2024-02-26
  • Online Date:2026-02-11
  • Published:2025-08-25
Article Data
Affiliations
History
  • Received:2024-02-26
Funding
Affiliations
    1.Langtai Biopharmaceutical Co., Ltd., Foshan, Guangdong 528225, China
    2.The General Hospital of Western Theater Command, Chengdu, Sichuan, 610083, China
References
Share
https://castjournals.cast.org.cn/joweb/jryx/EN/10.12048/j.issn.1674-229X.2025.08.005
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT