High Precision Ammonia Concentration Detection Method Based on Double Sinusoidal Compound Modulation Technology
收藏切换
Dachuang LI1, 2, 5, Mingjie ZHENG1, 2, Yaodong SONG3, 4, Youwen SUN1, 4, Xiaomin HU5, Biheng LIU5
Acta Photonica Sinica | 2026, 55(3) : 310 - 318
Less
收藏切换
Acta Photonica Sinica | 2026, 55(3): 310-318
• Instrumentation, Measurement and Metrology •
High Precision Ammonia Concentration Detection Method Based on Double Sinusoidal Compound Modulation Technology
Full
Dachuang LI1, 2, 5, Mingjie ZHENG1, 2, Yaodong SONG3, 4, Youwen SUN1, 4, Xiaomin HU5, Biheng LIU5
Affiliations
  • 1School of Electronic Information Engineering, Anhui University, Hefei 230601, China
  • 2School of Physics and Materials Engineering, Hefei Normal University, Hefei 230601, China
  • 3Anhui Daoji Quantum Technology Co., Ltd, Hefei 230013, China
  • 4Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
  • 5Quantum Information Laboratory, University of Science and Technology of China, Hefei 230026, China
Published: 2026-03-25 doi: 10.3788/gzxb20265503.0312001
Outline
收藏切换

Ammonia (NH₃) is a fundamental chemical agent extensively utilized in industrial synthesis, agricultural fertilizer production, and large-scale refrigeration systems. However, its leakage poses severe threats to both human physiological health and the atmospheric environment, necessitating the development of high-precision, real-time concentration monitoring techniques. Currently, Tunable Diode Laser Absorption Spectroscopy (TDLAS) combined with Wavelength Modulation Spectroscopy (WMS) is the preferred method for trace gas detection due to its high selectivity and sensitivity. Nevertheless, traditional TDLAS-WMS systems typically employ a low-frequency sawtooth wave for wavelength scanning. This conventional approach faces two critical technical bottlenecks: first, the inherent non-linearity and discontinuous nature of the sawtooth waveform lead to spectral energy dispersion and significant baseline fitting inaccuracies; second, the sawtooth scanning often overlaps with low-frequency environmental noise and mechanical vibrations, which expands the noise integration bandwidth of the lock-in amplifier and consequently limits the Signal-to-Noise Ratio (SNR) in complex industrial scenarios.

To overcome these limitations, this paper proposes an optimized detection method based on dual-sinusoidal compound modulation for second-harmonic signal extraction. The core innovation lies in the simultaneous application of a low-frequency sinusoidal scanning signal (fs) and a high-frequency sinusoidal modulation signal (fm) to achieve precise control of the laser frequency. Unlike the abrupt transitions of a sawtooth wave, the smooth and continuous nature of the dual-sinusoidal waveform effectively eliminates time-domain non-linearities, thereby suppressing baseline drifts at the source. Theoretically, this compound modulation concentrates the signal energy more efficiently near the specific harmonic sidebands (2fm), which significantly reduces the bandwidth requirements for the detection system and enhances its immunity to 1/f noise. By utilizing narrow-band lock-in amplification to extract the normalized second-harmonic (2f/1f) signal, the proposed method ensures a more robust and stable representation of the gas absorption line shape, providing a theoretical foundation for higher detection accuracy and lower cost.

The experimental validation was conducted using a 1 512 nm Distributed Feedback (DFB) laser and a 100 cm quartz gas cell under controlled laboratory conditions. A comprehensive platform based on a high-speed data acquisition card (NI-USB6363) and LabVIEW was established to compare the performance of the dual-sinusoidal method against the traditional sawtooth-plus-sine modulation. Precision calibration was performed using a combination of spatial cavity and fiber etalons to optimize the modulation depth. The experimental results demonstrate a substantial performance enhancement: the linear fitting degree (R2) between NH₃ concentration and the second-harmonic amplitude improved from 0.991 9 to 0.997 8. Quantitatively, the detection sensitivity was enhanced from 0.089 ppm to 0.053 ppm, representing a significant improvement of approximately 40.5%. Furthermore, Allan variance analysis confirms that the system achieves its optimum detection limit within a shorter integration time of 81.5 seconds, exhibiting superior long-term stability and a more concentrated Gaussian distribution of measurement data compared to the traditional scanning mode. These results quantitatively confirm that the dual-sine approach ensures higher repeatability, lower detection limits, and faster convergence to optimal precision.

In conclusion, this research successfully demonstrates that dual-sinusoidal compound modulation is a highly feasible and stable approach for high-precision trace gas detection. By circumventing the intrinsic flaws of sawtooth scanning-specifically baseline fitting errors and high sensitivity to low-frequency noise—this method provides a new technical pathway for the robust, real-time monitoring of NH₃ industrial emissions. The findings verify that the optimized system can maintain high accuracy and stability even in environments with significant physical disturbances. Future research will focus on further refining the modulation parameters and integrating advanced digital signal processing algorithms, such as adaptive filtering or artificial neural networks, to address multi-component gas interference in even more complex scenarios. Additionally, the development of integrated, FPGA-based hardware platforms and the incorporation of multipass cells will be explored to further enhance the detection limits and promote the widespread application of this technology in portable environmental monitoring and industrial safety systems.

TDLAS-WMS technology  /  Wavelength modulation spectroscopy  /  Second harmonic  /  Double sine modulation  /  Trace gas concentration detection
李大创, 郑明杰, 宋耀东, 孙友文, 胡晓敏, 柳必恒. 基于双正弦复合调制技术的高精度氨气浓度检测方法. 光子学报, 2026 , 55 (3) : 310 -318 . DOI: 10.3788/gzxb20265503.0312001
Dachuang LI, Mingjie ZHENG, Yaodong SONG, Youwen SUN, Xiaomin HU, Biheng LIU. High Precision Ammonia Concentration Detection Method Based on Double Sinusoidal Compound Modulation Technology[J]. Acta Photonica Sinica, 2026 , 55 (3) : 310 -318 . DOI: 10.3788/gzxb20265503.0312001
Year 2026 volume 55 Issue 3
117
51
Cite this Article
BibTeX
Article Info
doi: 10.3788/gzxb20265503.0312001
  • Receive Date:2025-10-21
  • Online Date:2026-10-10
  • Published:2026-03-25
Article Data
Affiliations
History
  • Received:2025-10-21
  • Accepted:2025-12-09
Affiliations
    1School of Electronic Information Engineering, Anhui University, Hefei 230601, China
    2School of Physics and Materials Engineering, Hefei Normal University, Hefei 230601, China
    3Anhui Daoji Quantum Technology Co., Ltd, Hefei 230013, China
    4Hefei Institute of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
    5Quantum Information Laboratory, University of Science and Technology of China, Hefei 230026, China
References
Share
https://castjournals.cast.org.cn/joweb/gzxb/EN/10.3788/gzxb20265503.0312001
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT