收藏切换
Effect of Aging Time on Insulation Deterioration of Power Electronic Transformers
收藏切换
Jianfu CHEN1, Xu CHENG1, 2, Yong CHEN1, 2, Xiaoyan ZHAO1, Wu CHEN  Senior Member, CPSS3, Zhan SHEN  Member, CPSS3
Journal of Power Supply | 2026, 24(5) : 339 - 348
Less
收藏切换
Journal of Power Supply | 2026, 24(5): 339-348
• Fault Diagnosis and Reliability •
Effect of Aging Time on Insulation Deterioration of Power Electronic Transformers
Full
Jianfu CHEN1, Xu CHENG1, 2, Yong CHEN1, 2, Xiaoyan ZHAO1, Wu CHEN  Senior Member, CPSS3, Zhan SHEN  Member, CPSS3
Affiliations
  • 1.Zhuhai Power Supply Bureau of Guangdong Power Grid Co., Ltd., Zhuhai 519000, China
  • 2.DC Power Distribution and Consumption Technology Research Center of Guangdong Power Grid Co., Ltd., Zhuhai 519000, China
  • 3.School of Electrical Engineering, Southeast University, Nanjing 210096, China
Published: 2026-05-30 doi: 10.13234/j.issn.2095-2805.2026.5.339
Outline
收藏切换

Power electronic transformer (PET) insulation system continue to deteriorate in high frequency, high voltage, short rise time pulse electrical stress and high temperature and other harsh environments; insulation discharge and breakdown risks are increasing significantly. In order to study the effect of high temperature thermal aging for PET on insulation deterioration under real operating conditions, the typical insulation polyimide (PI) of PET was aged at 250 ℃ for 3, 6, 9, 12 days, and then 20 kHz, 4 kV, 300 ns pulsed voltage was used to simulate PET operating conditions. The partial discharge and breakdown voltage of insulation were tested, and time-resolved partial discharge spectrum (TRPD), discharge times, average discharge amplitude, and maximum discharge amplitude were used to characterize the degree of insulation deterioration. The results show that after aging, the TRPD pattern of PI films changes from single peak to multiple peaks, showing a phenomenon of clustering. At the same time, with the increase of aging time, the number of partial discharges, average discharge amplitude and maximum discharge amplitude increase by 47.3%, 61.1% and 41.9%, respectively, and the degree of insulation deterioration was significantly deepened. The breakdown voltage distribution of PI film conforms to Weibull distribution and decreases with aging time, from the initial 4 667 V to 4 457 V, a decrease of 4.5%. Therefore, the effect of aging time on the deterioration of PET insulation is obtained, which has certain guiding significance for the reliability analysis and optimal design of PET insulation.

Power electronic transformer  /  pulsed electrical stress  /  high temperature deterioration  /  partial discharges  /  breakdown voltage
陈建福, 程旭, 陈勇, 赵晓燕, 陈武中国电源学会高级会员, 沈湛中国电源学会会员. 老化时间对电力电子变压器绝缘劣化的影响. 电源学报, 2026 , 24 (5) : 339 -348 . DOI: 10.13234/j.issn.2095-2805.2026.5.339
Jianfu CHEN, Xu CHENG, Yong CHEN, Xiaoyan ZHAO, Wu CHEN, Zhan SHEN. Effect of Aging Time on Insulation Deterioration of Power Electronic Transformers[J]. Journal of Power Supply, 2026 , 24 (5) : 339 -348 . DOI: 10.13234/j.issn.2095-2805.2026.5.339
  • National Natural Science Foundation of China(52207191)
  • China Southern Power Grid Company Technology Project(030400KK52222021)
Year 2026 volume 24 Issue 5
36
6
Cite this Article
BibTeX
Article Info
doi: 10.13234/j.issn.2095-2805.2026.5.339
  • Receive Date:2025-02-09
  • Online Date:2026-10-29
  • Published:2026-05-30
Article Data
Affiliations
History
  • Received:2025-02-09
  • Revised:2025-03-23
  • Accepted:2025-04-08
Funding
National Natural Science Foundation of China(52207191)
China Southern Power Grid Company Technology Project(030400KK52222021)
Affiliations
    1.Zhuhai Power Supply Bureau of Guangdong Power Grid Co., Ltd., Zhuhai 519000, China
    2.DC Power Distribution and Consumption Technology Research Center of Guangdong Power Grid Co., Ltd., Zhuhai 519000, China
    3.School of Electrical Engineering, Southeast University, Nanjing 210096, China
References
Share
https://castjournals.cast.org.cn/joweb/dyxb/EN/10.13234/j.issn.2095-2805.2026.5.339
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT