收藏切换
Fault Tolerant Control of Six-phase Electric-drive-reconstructed V2G System Under Open-phase Fault
收藏切换
Feng YU1, Delin HU1, Zhihao ZHU2
Journal of Power Supply | 2026, 24(1) : 338 - 346
Less
收藏切换
Journal of Power Supply | 2026, 24(1): 338-346
• Fault Diagnosis and Reliability •
Fault Tolerant Control of Six-phase Electric-drive-reconstructed V2G System Under Open-phase Fault
Full
Feng YU1, Delin HU1, Zhihao ZHU2
Affiliations
  • 1.School of Electrical Engineering, Nantong University, Nantong 226019, China
  • 2.School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
Published: 2026-01-30 doi: 10.13234/j.issn.2095-2805.2026.1.338
Outline
收藏切换

Due to its advantages such as low cost and high space utilization, the electric-drive-reconstructed vehicle-to-grid (V2G) system has become a research hotspot recently. The open-phase fault is inevitable during the operation of the electric-drive-reconstructed V2G system, under which the grid-side current will fail to keep balance and the motor torque may even increase sharply. Therefore, there are many potential safety problems. Aimed at these problems, an electric-drive-reconstructed V2G system based on an asymmetric six-phase permanent magnet synchronous motor is constructed, and its fault tolerant control scheme under open-phase fault is proposed. First, the circuit topology of the six-phase electric-drive-reconstructed V2G system is analyzed. Second, the relationship between the grid-side current and the motor’s x-y space current is deduced, so that the working mechanism of the system during its normal operation is obtained. Third, a fault tolerant operation scheme for the six-phase electric-drive-reconstructed V2G system under open-phase fault is put forward by injecting current to the o1-o2 space of the motor, so as to produce zero torque and balanced grid-side current and ensure the system’s normal operation under open-phase fault. Finally, a 270 W experimental prototype was built, and experimental results verified the feasibility of the system and its fault tolerant operation scheme.

Vehicle-to-grid (V2G)  /  electric-drive-reconstructed  /  open-phase fault  /  six-phase permanent magnet synchronous motor  /  fault tolerant operation
於锋, 胡德林, 朱志豪. 六相电驱重构型V2G系统断相故障容错控制. 电源学报, 2026 , 24 (1) : 338 -346 . DOI: 10.13234/j.issn.2095-2805.2026.1.338
Feng YU, Delin HU, Zhihao ZHU. Fault Tolerant Control of Six-phase Electric-drive-reconstructed V2G System Under Open-phase Fault[J]. Journal of Power Supply, 2026 , 24 (1) : 338 -346 . DOI: 10.13234/j.issn.2095-2805.2026.1.338
  • National Natural Science Foundation of China(52177051)
Year 2026 volume 24 Issue 1
46
3
Cite this Article
BibTeX
Article Info
doi: 10.13234/j.issn.2095-2805.2026.1.338
  • Receive Date:2023-06-20
  • Online Date:2026-10-26
  • Published:2026-01-30
Article Data
Affiliations
History
  • Received:2023-06-20
  • Revised:2023-08-22
  • Accepted:2023-09-12
Funding
National Natural Science Foundation of China(52177051)
Affiliations
    1.School of Electrical Engineering, Nantong University, Nantong 226019, China
    2.School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China
References
Share
https://castjournals.cast.org.cn/joweb/dyxb/EN/10.13234/j.issn.2095-2805.2026.1.338
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT