收藏切换

Static var generator(SVG)can governance power quality,energy conservation and reduce consumption,furthermore it is an energy consumption product.The reasonable evaluation of the energy saving of the device has become an urgent problem to be solved. The power saving measurement technology of products was studied,and it was found that the existing power saving verification methods are not test methods. Because the field conditions are not unified,the verification results are not comparable. They can not be the data support of energy saving evaluation. At present,there is no set of effective testing methods in the field of inspection and testing that can be used for the power saving measurement of products in third-party testing laboratories,which makes both the testing work and energy saving evaluation work cannot be carried out.In order to make up for the above proposed detection technology gap,the innovative test method of design simulation resistance was proposed,so as to help complete the power saving measurement work. And a test platform was set up in the laboratory,to verify the feasibility and correctness of the method,and to assess the dispersion of the measurement results.The final conclusion is that the proposed method can be used for the third-party laboratory to complete the power saving measurement,flexible and controllable test conditions,can meet the requirements of various working conditions of the manufacturer,and the measurement results are comparable,can become the data support of energy saving evaluation,promote product iteration and update,and promote the progress of the industry.

static var generator(SVG)  /  energy conservation  /  power savings measurement method
Lin LU, Fanting KONG, Chunxiang ZHANG, Jian CHEN, Lianjie WANG. Research on Power Savings Measurement Method of Static Var Generator[J]. Electric Drive, 2025 , 55 (1) : 90 -96 . DOI: 10.19457/j.1001-2095.dqcd26124
Year 2025 volume 55 Issue 1
PDF
202
89
Cite this Article
BibTeX
Article Info
doi: 10.19457/j.1001-2095.dqcd26124
  • Receive Date:2024-08-21
  • Online Date:2025-10-29
  • Published:2025-01-20
Article Data
Affiliations
History
  • Received:2024-08-21
  • Revised:2024-10-08
Funding
Affiliations
    1 Tianjin Tianchuan Electric Control Equipment Test Co.,Ltd.,Tianjin 300180,China
    2 Tianjin Research Institute of Electric Science Co.,Ltd.,Tianjin 300399,China
References
Share
https://castjournals.cast.org.cn/joweb/dqcd/EN/10.19457/j.1001-2095.dqcd26124
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数

Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)

Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT