收藏切换
Albumin-based fluorescent sensor array for differentiating of tetracyclines through host-guest recognitions
收藏切换
PDF
Zhongyong Xua, Jun Penga, Wenxing Zhangb, Lei Wanga, Xiongzhi Xianga, Bin Liua
Chinese Chemical Letters | 2026, 37(6) : 111525
Less
收藏切换
Chinese Chemical Letters | 2026, 37(6): 111525
• Communication •
Albumin-based fluorescent sensor array for differentiating of tetracyclines through host-guest recognitions
Full
Zhongyong Xua, Jun Penga, Wenxing Zhangb, Lei Wanga, Xiongzhi Xianga, Bin Liua
Affiliations
  • aState Key Laboratory of Fine Chemicals, College of Material Science and Engineering, Shenzhen University, Shenzhen 518060, China
  • bAdvanced Materials and Devices Laboratory, School of Materials Science and Engineering, Hanshan Normal University, Chaozhou 521041, China
About Author:

CRediT authorship contribution statement

Zhongyong Xu: Writing – original draft, Methodology, Formal analysis, Data curation.

Jun Peng: Investigation.

Wenxing Zhang: Supervision.

Lei Wang: Supervision, Resources.

Xiongzhi Xiang: Supervision, Data curation.

Bin Liu: Writing – review & editing, Validation, Supervision, Project administration, Investigation.

Published: 2026-06-15 doi: 10.1016/j.cclet.2025.111525
Outline
收藏切换

The overuse and improper disposal of tetracyclines raise significant environmental and public health concerns due to their persistent ecotoxicological effects. However, there is still a lack of simple, readily available, and effective method for simultaneously detecting multiple tetracyclines. Herein, we present a simple fluorescent sensor array for the detection and identification of multiple tetracyclines (including tetracycline, oxytetracycline, chlortetracycline, and doxycycline) based on host-guest recognitions between albumin (host) and tetracycline (guest). Upon entering the hydrophobic cavity of albumin, tetracycline exhibits a significant enhancement in its intrinsic fluorescence. The differential binding affinity of two albumins to four tetracyclines resulted in different fluorescent responses, creating distinct fluorescence patterns for each tetracycline. With the assistance of machine learning technique, including linear discriminant analysis (LDA) and hierarchical cluster analysis (HCA), this sensor array demonstrated the significant discrimination and classification capabilities for four common tetracyclines and their mixtures with 100% accuracy. Additionally, the array has been successfully applied to differentiate tetracyclines in real food samples. The spiked antibiotics in water sample were determined with a satisfactory recovery of 96.33%–106.5%. This work offers a simple but promising method for differentiating tetracycline antibiotics and presents a versatile strategy for sensor array design.

Tetracyclines  /  Fluorescent sensor array  /  Albumin  /  Host-guest  /  Food samples
Zhongyong Xu, Jun Peng, Wenxing Zhang, Lei Wang, Xiongzhi Xiang, Bin Liu. Albumin-based fluorescent sensor array for differentiating of tetracyclines through host-guest recognitions[J]. Chinese Chemical Letters, 2026 , 37 (6) : 111525 - . DOI: 10.1016/j.cclet.2025.111525
Tetracyclines, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC), and doxycycline (DOC), are broad-spectrum antibiotics effective against bacteria, atypical pathogens, and protozoan [1–3]. Their potent antibacterial properties drive widespread use in agriculture, aquaculture, and livestock industries. However, > 75% of tetracyclines residues are excreted in active form into the environment through urine, feces, and manure from animal after medication [4]. The residues of these tetracyclines in the environment fosters the proliferation and spread of antibiotic-resistant bacteria and superbugs, significantly increasing the difficulty and challenges faced by the healthcare system in managing infectious diseases [5]. On the other hand, different types of tetracyclines have different physicochemical properties (Table S1 in Supporting information), leading to variations in their toxicity [6,7]. Thus, the maximum residue limits (MRLs) for different tetracyclines vary significantly. For example, China stipulated the maximum sewage discharge of TCs for pharmaceutical industry, with 1.634 mmol/L for TC, 2.729 mmol/L for OTC, and 1.183 mmol/L for CTC (GB8978–1996). Therefore, there is an urgent need to develop a method capable of accurate detection and differentiation of tetracyclines.
Current analytical methods for tetracyclines detection, including enzyme-linked immunosorbent assays [8], capillary electrophoresis [9], surface-enhanced Raman scattering [10], fluorescence [11,12], and high-performance liquid chromatography [13], demonstrate high sensitivity but require repetitive operations for comprehensive analysis, significantly complicating multi-tetracycline detection procedures. The emergence of sensor array has addressed this challenge, offering a more comprehensive and versatile approach [14–17]. Sensor array, inspired by mammalian gustatory and olfactory systems, can provide an unique fingerprint pattern recognition for multitarget analytes [18–25]. Using pattern recognition algorithms, such as linear discriminant analysis (LDA) and hierarchical cluster analysis (HCA), these fingerprint patterns can be classified into distinct clusters, enabling effective discrimination and classification [26,27]. Recently, several fluorescent sensor arrays for tetracyclines have been reported, the detection of a single tetracycline and identification of different types of tetracyclines have been achieved (Table S2 in Supporting information) [28–35]. However, a simple, labor-saving, and easily accessible sensor array method that allows for the accurate distinction of different tetracyclines is still lacking.
Herein, we report an easily accessible sensor array that contains two common natural albumins. Previous research has demonstrated that the fluorescence of tetracyclines increases significantly when they form a complex with albumin through host-guest reaction, because tetracycline antibiotics can enter the hydrophobic binding cavities of albumin, limiting their rotation [36–38]. Based on this principle, we selected human serum albumin (HSA, purchased from the Sigma Aldrich) and bovine serum albumin (BSA) as sensing elements, due to their structural sequence difference of approximately 24% (Scheme 1a) [39,40]. Moreover, two albumins are readily accessible commercially and are available at a low cost. The binding interaction of these tetracyclines with albumins modulated the fluorescent response of the array, resulting in distinct fluorescent signals for each tetracycline species. Assisted by machine learning technique, this simple sensor array enables the simultaneous detection of four tetracycline species, as well as the recognition of different mixing ratios and the quantification of individual tetracycline species (Scheme 1b). Finally, this array successfully discriminated between different tetracycline species in real samples.
To confirm the albumin-based sensor array's effectiveness, we firstly studied the fluorescence spectra of tetracyclines binding to albumin. Each tetracycline species has multiple hydroxyl groups that allow it to bind to albumin (Fig. 1a). Figs. 1b–e reveals that tetracyclines exhibit minimal fluorescence in phosphate buffered saline (PBS) buffer but show an increase upon addition of albumin, due to the binding between tetracycline and the hydrophobic pocket of albumin. Notably, different fluorescence responses of tetracycline species to albumins were observed, due to different binding modes. Previous studies have demonstrated that tetracycline exhibits different binding constants with two albumins (Table S3 in Supporting information). To explore the binding interactions, we employed the molecular docking technique. Previous studies show tetracycline primarily binds to the IIA domain of albumin [11]. The docking results indicated that tetracycline undergoes conformational changes when entering the hydrophobic cavities of the two albumins (Figs. 1f and g, Fig. S1 in Supporting information). As illustrated in Fig. S2 (Supporting information), there are significant differences in the binding energies between different tetracyclines and albumin. Meanwhile, the hydrogen bonds formed by tetracyclines within the cavity vary depending on the specific type of tetracycline. The varying amino acid environments lead to unique fluorescence traits in the complexes, highlighting the different binding interactions of tetracycline toward albumins. After assessing the fluorescence response of tetracyclines with two albumins, we developed an albumin-based sensor array to differentiate between tetracycline species (Fig. 1h).
The detection performance of the array for tetracyclines was evaluated using the maximum fluorescence intensity of albumin-tetracycline complexes. Fig. 2a demonstrates that HSA and BSA produce distinct fluorescent responses to four different tetracyclines at a concentration of 20 µmol/L. The heatmap shows the unique fingerprints of these tetracycline species, enabling effective differentiation (Fig. 2b and Fig. S3 in Supporting information). The response patterns matrix (2 elements × 4 analytes × 5 replicates) was analyzed using LDA and HCA. Fig. 2c shows the LDA plot of the array, which produced four distinct clusters, achieving 100% classification accuracy for each tetracycline, as confirmed by cross-validation (Tables S4 and S5 in Supporting information). The HCA plot also correctly grouped all data without misclassification (Fig. 2d). Following the successful detection, we lowered the tetracycline concentration from 20 µmol/L to 3 µmol/L to test the identification capability of the array. Distinct heatmaps for each tetracycline concentration were generated and analyzed using LDA (Figs. 2e–g) and HCA (Fig. S4 in Supporting information). The analysis showed that all four tetracyclines were accurately distinguished without overlap, achieving 100% accuracy (Tables S6–S13 in Supporting information). These results highlight the strong ability of the array to discriminate between tetracyclines. Furthermore, two blind samples were used to further assess the predictive capability of the array for unknown samples. The two blind samples exhibited distinct fluorescent responses (Fig. 2h), and the raw data were accurately classified using an HCA plot (Fig. 2i). As illustrated in Fig. 2j, the two samples were correctly identified through an LDA plot (Table S14 in Supporting information). The aforementioned results indicate that the arrays can be used for the discrimination of unknown samples.
To assess the quantitative detection capabilities of the designed array, we recorded its fluorescence responses to individual tetracyclines at various concentrations, as shown in the radar charts (Fig. 3a and Fig. S5 in Supporting information). The array exhibited distinct responses to four different tetracycline species. Unique heatmaps for each tetracycline species were also generated (Fig. 3b and Fig. S6 in Supporting information). The LDA plot demonstrated that TC at different concentrations were accurately clustered without overlap (Fig. 3c). LD1 effectively described the distribution pattern of tetracyclines due to over 99% in the LDA. A strong linear regression was observed between LD1 and TC concentrations, ranging from 3 µmol/L to 20 µmol/L (R2 = 0.98) (Fig. 3d). Furthermore, similar linear correlations were noted for three additional tetracyclines (Fig. S7 in Supporting information). Specifically, the linear relationships between LD1 and the other tetracyclines were within the concentration range of 3–20 µmol/L, yielding R2 values of 0.98 for OTC, 0.96 for CTC, and 0.97 for DOC, respectively. The limits of detection were 2.82 µmol/L for TC, 1.83 µmol/L for OTC, 1.99 µmol/L for CTC, and 1.03 µmol/L for DOC. These findings indicate that the array possesses exceptional quantitative detection capabilities.
To showcase the array's ability to discriminate tetracycline mixtures, OTC-DOC mixtures at a total concentration of 20 µmol/L were tested. Fig. 3e presents a heatmap of the raw response data, revealing distinct color patterns for different mixtures, thereby highlighting the discrimination potential. Fig. 3f illustrates that the HCA plot accurately clusters these samples without errors. The LDA plot successfully classifies OTC-DOC mixtures with varying ratios (Fig. 3g and Tables S15 and S16 in Supporting information), while the violin plot emphasizes a significant difference in LD1 scores among these binary mixtures (Fig. 3h). Notably, a strong linear correlation is observed between the LD1 scores and the OTC content in the binary mixtures, which underscores the exceptional discriminative capability of the array for tetracyclines (Fig. 3i). These results demonstrate the potential application of the sensor array in real-sample analysis.
Given the alarming threat of tetracyclines residue in animal products and environment to human health, [41] the array was employed to explore the potential application in beef and lake water samples. Fresh beef was pretreated according to experimental section, and the resulting solution was used to evaluate the array through spiking analysis. Fig. 4a displays a distinct heatmap for four tetracyclines and their mixtures in the beef sample. The LDA plot shows clear group classification of the spiked samples with no overlap (Fig. 4b). Additionally, the violin plot in Fig. 4c highlights a significant difference LD1 scores between control and spiked samples. The HCA plot showed that tetracyclines and their mixtures could be clearly distinguished without any confusion or misclassification (Fig. S8 in Supporting information). Furthermore, the fluorescence response of the array to lake water sample was also detected and analyzed. From the heatmap in Fig. 4d, it becomes evident that the array can differentiate between tetracyclines. HCA plot exhibits no confusion for tetracyclines in water sample (Fig. 4e). As shown in Figs. 4f and g, as expected, each of the four tetracyclines was discriminated from each other. The interference resistance experiment demonstrated that common ions, amino acids, and proteins had no impact on the discrimination performance of the array, indicating that the array possesses excellent anti-interference capability (Fig. S9 in Supporting information). As shown in Tables S17 and S18 (Supporting information), the recovery rates ranged from 96.33% to 106.5% with RSD value (<1.56%). These results underscore the potential of the sensor array to discriminate tetracyclines and their mixtures in real samples.
In summary, we herein developed a protein-based sensor array for the differentiation of tetracyclines based on varying binding affinities between albumins and tetracyclines. Assisted by the machine learning techniques, this sensor array achieved a 100% identification accuracy for individual tetracyclines and their mixtures. Furthermore, this method can be utilized to differentiate tetracyclines and their mixtures in actual samples in the environment and food. The design strategy underlying this approach may offer a novel pathway for the advancement of innovative sensor arrays.
1
M.C. Roberts, Clin. Infect. Dis. 36 (2003) 462–467.
2
Q. Liao, H.W. Rong, M.H. Zhao, et al., Sci. Total Environ. 757 (2021) 143981.
3
J. Leichtweis, Y. Vieira, N. Welter, et al., Process Saf. Environ. 160 (2022) 25–40.
4
L. Xu, H. Zhang, P. Xiong, et al., Sci. Total Environ. 753 (2021) 141975.
5
J. Scaria, K.V. Anupama, P.V. Nidheesh, Sci. Total Environ. 771 (2021) 145291.
6
J. Ye, Y. Du, L. Wang, et al., Toxins 9 (2017) 53.
7
F. Ahmadijokani, H. Molavi, S. Tajahmadi, et al., Coord. Chem. Rev. 464 (2022) 214562.
8
W. Guo, L. Vilaplana, J. Hansson, et al., Biosens. Bioelectron. 163 (2020) 112279.
9
P. Kowalski, J. Pharmaceut. Biomed. 47 (2008) 487–493.
10
M. Rong, Y. Huang, C. Lin, et al., TrAC Trend. Anal. Chem. 178 (2024) 117839.
11
M. Zhang, S. Zhang, Z. Xu, et al., Talanta 266 (2024) 124982.
12
Z. Zhang, H. Zhang, D. Tian, et al., Coord. Chem. Rev. 498 (2024) 215455.
13
P. Moudgil, J.S. Bedi, R.S. Aulakh, et al., Food Anal. Method 12 (2019) 338–346.
14
J.R. Askim, M. Mahmoudi, K.S. Suslick, Chem. Soc. Rev. 42 (2013) 8649–8682.
15
Z. Xu, Y. Zhan, S. Zhang, et al., Chem. Commun. 61 (2025) 564–567.
16
S. Chen, X. Zhang, Y. Yu, et al., Chin. Chem. Lett. 32 (2021) 3043–3047.
17
G. Wang, Q. Qiao, W. Jia, et al., Chin. Chem. Lett. 36 (2025) 110130.
18
J.J. Lavigne, E.V. Anslyn, Angew. Chem. Int. Ed. 40 (2001) 3118–3130.
19
Y. Liu, T. Minami, R. Nishiyabu, et al., J. Am. Chem. Soc. 135 (2013) 7705–7712.
20
M. De, S. Rana, H. Akpinar, et al., Nat. Chem. 1 (2009) 461–465.
21
C.C. You, O.R. Miranda, B. Gider, et al., Nat. Nanotechnol. 2 (2007) 318–323.
22
S. Rana, N.D.B. Le, R. Mout, et al., Nat. Nanotechnol. 10 (2015) 65–69.
23
N. Das Saha, S. Pradhan, R. Sasmal, et al., J. Am. Chem. Soc. 144 (2022) 14363–14379.
24
M.A. Ivy, L.T. Gallagher, A.D. Ellington, et al., Chem. Sci. 3 (2012) 1773–1779.
25
S. Hasegawa, T. Sawada, T. Serizawa, ACS Appl. Bio. Mater. 6 (2023) 4598–4602.
26
X.Y. Lu, H.P. Wu, H. Ma, et al., Anal. Chem. 96 (2024) 7959–7975.
27
S. Stewart, M.A. Ivy, E.V. Anslyn, Chem. Soc. Rev. 43 (2014) 70–84.
28
S. Lu, X. Dong, B. Zhang, et al., J. Mol. Liq. 351 (2022) 118371.
29
Y. Zhang, T. Wang, H. Guo, et al., Biosens. Bioelectron. 231 (2023) 115266.
30
B. Liu, Z. Tang, J. Pan, et al., ACS Sens. 9 (2024) 433–443.
31
J. Zhu, Y. Wu, C. Xue, et al., Chem. Eng. J. 500 (2024) 156839.
32
X. Zhou, H. Wu, X. Chen, et al., Food Chem. 438 (2024) 137983.
33
J. Xu, X. Chen, H. Zhou, et al., Talanta 266 (2024) 125122.
34
L. Zhu, Q. Wu, X. Mei, et al., Adv. Compos. Hybrid Mater. 6 (2023) 221.
35
B. Liu, J. Liu, J. Pan, et al., Sens. Actuators B: Chem. 397 (2023) 134671.
36
M. Mukherjee, P. Saha Sardar, S.K. Ghorai, et al., PLoS One 8 (2013) e60940.
37
L. Ding, Y. Zhao, H. Li, et al., J. Hazard. Mater. 416 (2021) 125759.
38
S.K. Ghorai, S.K. Samanta, M. Mukherjee, et al., Inorg. Chem. 52 (2013) 1476–1487.
39
A. Bujacz, Acta Crystallogr. Sect. D 68 (2012) 1278–1289.
40
Y. Wang, F. Huo, C. Yin, J. Phys. Chem. B 128 (2024) 1121–1138.
41
L. Charuaud, E. Jarde, A. Jaffrezic, et al., J. Hazard. Mater. 361 (2019) 169–186.
Year 2026 volume 37 Issue 6
PDF
74
42
Cite this Article
BibTeX
Article Info
doi: 10.1016/j.cclet.2025.111525
  • Receive Date:2025-03-24
  • Online Date:2026-10-27
  • Published:2026-06-15
Article Data
Affiliations
History
  • Received:2025-03-24
  • Revised:2025-06-18
  • Accepted:2025-06-29
Affiliations
    aState Key Laboratory of Fine Chemicals, College of Material Science and Engineering, Shenzhen University, Shenzhen 518060, China
    bAdvanced Materials and Devices Laboratory, School of Materials Science and Engineering, Hanshan Normal University, Chaozhou 521041, China

Corresponding:

*

E-mail addresses: (W. Zhang)
References
Share
https://castjournals.cast.org.cn/joweb/ccl/EN/10.1016/j.cclet.2025.111525
Share to
QR

Scan QR to access full text

Cite this article
BibTeX
Citations
表12种不同金属材料的力学参数
科
Family
属数
Number of
genus
种数
Number of
species
占总种数比例
Percentage of
total species (%)
属
Genus
种数
Number of
species
占总种数比例
Percentage of total
species (%)
鹅膏菌科Amanitaceae 2 11 5.26 鹅膏菌属 Amanita 10 4.78
小菇科 Mycenaceae 2 12 5.74 丝盖伞属 Inocybe 5 2.39
多孔菌科 Polyporaceae 8 14 6.70 蜡蘑属 Laccaria 5 2.39
红菇科 Russulaceae 3 23 11.00 小皮伞属 Marasmius 6 2.87
小菇属 Mycena 11 5.26
光柄菇属 Pluteus 5 2.39
红菇属 Russula 17 8.13
栓菌属 Trametes 5 2.39
关闭全屏
  • BibTeX
  • EndNote
  • RefWorks
  • TxT